| Name | Hern Kelly Forceps |
| Lead Time | 0-3 days |
| Specialty | Obstetrics & Gynecology-Forceps – Ovum & Placenta |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | AGO INDUSTRY |
| Sterility | Non-Sterile |
| Usage | Reusable |
Hern Kelly Forceps
curved, 19.0 mm, 13″ (33.0 cm) Hern Kelly Forceps are designed to grasp and remove tissue in the uterus during procedures. The forceps feature coarse teeth on the hollow jaws to firmly grasp the tissue. The blades are curved to easily navigate through the birth canal and reach difficult areas.
SKU:
AGO-01-1352
Category: Forceps
Description
Reviews (0)
Be the first to review “Hern Kelly Forceps” Cancel reply
Shipping & Delivery
Related products
Glenner Hysterectomy Forceps
jaws curved upward & to the side, w/ longitudinal serrations & single tooth, 8-1/4" (21.0 cm) Glenner Hysterectomy Forceps are commonly used in hysterectomy procedures to clamp the tough ligament no both sides of the uterus. The longitudinal serrations and single tooth are ideal in hysterectomy for securely grasping lower ligaments. The forceps are available with the clamps curving left or right to accommodate a range of cases.
Bierer Tenaculum
angled jaws, 5x6 teeth, 9" (22.9 cm) Bierer Tenaculum is commonly used in gynecology to stabilize a woman's cervix or uterus during a procedure. The tenaculum features angled jaws and inward facing hooks with 5X6 teeth to firmly grasp the tissue. The ring handles have a lock mechanism to hold the blades in various positions.
Faure Peritoneal Clamp Forceps
slight curve, 8-1/4" (21.0 cm) Faure Peritoneal Clamp Forceps are commonly used to remove the peritoneum tissue from the pelvic cavity for gynecological procedures. The ring handles feature a locking mechanism to hold the forceps in position. The slightly curved serrated blades keep a firm grip on the peritoneal tissue during the procedure.
Braun Tenaculum Forceps
Colins Uterine Elevating Forceps
Bill Traction Handle
for use w/ all standard handle type o.b. forceps Bill Traction Handle is designed to increase the accuracy of traction to the path of least resistance. The handle features a claw that is applied to the finger guards of standard obstetrical forceps. The claw is then attached via a vertical rod and movable joint to a handle grip that is held by the obstetrician.

Reviews
There are no reviews yet.